The Delta range is ideal for large, single-family houses and for installations that consume large amounts of domestic hot water: jacuzzi and hydro-massage baths, multi-jet showers, etc.

 
Mark checkbox to compare
Product (*)
Description (*)
Delta Classic G20 Delta Classic G20

Combined natural gas-fired boiler and water heater with atmospheric burner
Chimney Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 26,8
  • Output power max. (80/60°C) (kW) : 23,2
  • Capacity (total) (L) : 178,5
  • Dim. - Width or Diameter (w/o conn.) (mm) : 540
  • Dim. - Depth (w/o conn.) (mm) : 685
  • Dim. - Height (w/o conn.) (mm) : 1697
  • Peak flow at 40 °C (L/10’) : 266
 
Delta Classic G25 Delta Classic G25

Combined natural gas-fired boiler and water heater with atmospheric burner
Chimney Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 33,2
  • Output power max. (80/60°C) (kW) : 28,7
  • Capacity (total) (L) : 167,5
  • Dim. - Width or Diameter (w/o conn.) (mm) : 540
  • Dim. - Depth (w/o conn.) (mm) : 685
  • Dim. - Height (w/o conn.) (mm) : 1697
  • Peak flow at 40 °C (L/10’) : 339
 
Delta Classic G30 Delta Classic G30

Combined natural gas-fired boiler and water heater with atmospheric burner
Chimney Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 39
  • Output power max. (80/60°C) (kW) : 34
  • Capacity (total) (L) : 167,5
  • Dim. - Width or Diameter (w/o conn.) (mm) : 540
  • Dim. - Depth (w/o conn.) (mm) : 685
  • Dim. - Height (w/o conn.) (mm) : 1697
  • Peak flow at 40 °C (L/10’) : 339
 
Delta Classic P30 Delta Classic P30

Combined propane gas-fired boiler and water heater with atmospheric burner
Chimney Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 40
  • Output power max. (80/60°C) (kW) : 34,4
  • Capacity (total) (L) : 167,5
  • Gas type () : Propane
  • Dim. - Width or Diameter (w/o conn.) (mm) : 540
  • Dim. - Depth (w/o conn.) (mm) : 685
  • Dim. - Height (w/o conn.) (mm) : 1697
  • Peak flow at 40 °C (L/10’) : 339
 
Delta Performance 25 Delta Performance 25

Combined fuel oil/gas-fired boiler and water heater (chimney)
Chimney Floor installation Dual-fuel (gas and fuel oil compatible) [ key ]
 
  • Input max. (heating) (kW) : 33
  • Input min. (heating) (kW) : 25
  • Output power max. (80/60°C) (kW) : 29
  • Capacity (total) (L) : 157
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 565/818
  • Dim. - Height (w/o conn.) (mm) : 1497
  • Peak flow at 40 °C (L/10’) : 268
 
Delta Performance 35 Delta Performance 35

Combined fuel oil/gas-fired boiler and water heater (chimney)
Chimney Floor installation Dual-fuel (gas and fuel oil compatible) [ key ]
 
  • Input max. (heating) (kW) : 45
  • Input min. (heating) (kW) : 33
  • Output power max. (80/60°C) (kW) : 40
  • Capacity (total) (L) : 178
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 565/818
  • Dim. - Height (w/o conn.) (mm) : 1697
  • Peak flow at 40 °C (L/10’) : 285
 
Delta Performance 45 Delta Performance 45

Combined fuel oil/gas-fired boiler and water heater (chimney)
Chimney Floor installation Dual-fuel (gas and fuel oil compatible) [ key ]
 
  • Input max. (heating) (kW) : 61
  • Input min. (heating) (kW) : 42
  • Output power max. (80/60°C) (kW) : 54
  • Capacity (total) (L) : 132
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 565/818
  • Dim. - Height (w/o conn.) (mm) : 1497
  • Peak flow at 40 °C (L/10’) : 316
 
Delta Performance 55 Delta Performance 55

Combined fuel oil/gas-fired boiler and water heater (chimney)
Chimney Floor installation Dual-fuel (gas and fuel oil compatible) [ key ]
 
  • Input max. (heating) (kW) : 69
  • Input min. (heating) (kW) : 50
  • Output power max. (80/60°C) (kW) : 62
  • Capacity (total) (L) : 162
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 565/848
  • Dim. - Height (w/o conn.) (mm) : 1697
  • Peak flow at 40 °C (L/10’) : 362
 
Delta Performance 35 FV Delta Performance 35 FV

Combined fuel oil-fired boiler and water heater (balanced flue)
Floor installation Fuel oil [ key ]
 
  • Input max. (heating) (kW) : 34,9
  • Output power max. (80/60°C) (kW) : 32,6
  • Capacity (total) (L) : 127
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 800
  • Dim. - Height (w/o conn.) (mm) : 1585
  • Peak flow at 40 °C (L/10’) : 291
 
Delta Performance 35 SV Delta Performance 35 SV

Combined gas-fired boiler and water heater with stabile pre-mix burner (balanced flue)
Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 34,9
  • Output power max. (80/60°C) (kW) : 31,9
  • Capacity (total) (L) : 127
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 800
  • Dim. - Height (w/o conn.) (mm) : 1585
  • Peak flow at 40 °C (L/10’) : 291
 
Delta Performance 35 MV Delta Performance 35 MV

Combined gas-fired boiler and water heater with modulating pre-mix burner (balanced flue)
Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 34,9
  • Input min. (heating) (kW) : 10
  • Output power max. (80/60°C) (kW) : 32
  • Efficiency (max. output) 80/60°C (%) : 92,9
  • Capacity (total) (L) : 127
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 800
  • Dim. - Height (w/o conn.) (mm) : 1585
  • Peak flow at 40 °C (L/10’) : 291
 
Delta Performance 50 FV Delta Performance 50 FV

Combined fuel oil-fired boiler and water heater (balanced flue)
Floor installation Fuel oil [ key ]
 
  • Input max. (heating) (kW) : 50
  • Output power max. (80/60°C) (kW) : 46,8
  • Capacity (total) (L) : 162
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 800
  • Dim. - Height (w/o conn.) (mm) : 1830
  • Peak flow at 40 °C (L/10’) : 377
 
Delta Performance 50 SV Delta Performance 50 SV

Combined gas-fired boiler and water heater with stabile pre-mix burner (balanced flue)
Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 50
  • Output power max. (80/60°C) (kW) : 46,7
  • Capacity (total) (L) : 162
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 800
  • Dim. - Height (w/o conn.) (mm) : 1830
  • Peak flow at 40 °C (L/10’) : 328
 
Delta Performance 50 MV Delta Performance 50 MV

Combined gas-fired boiler and water heater with modulating pre-mix burner (balanced flue)
Floor installation Gas [ key ]
 
  • Input max. (heating) (kW) : 50
  • Input min. (heating) (kW) : 15
  • Output power max. (80/60°C) (kW) : 46,7
  • Efficiency (max. output) 80/60°C (%) : 93
  • Capacity (total) (L) : 162
  • Dim. - Width or Diameter (w/o conn.) (mm) : 542
  • Dim. - Depth (w/o conn.) (mm) : 800
  • Dim. - Height (w/o conn.) (mm) : 1830
  • Peak flow at 40 °C (L/10’) : 328
 
Compare
(*)
  • The product range offered can vary according to country. Please consult your distributor.
  • All values indicated on this site are provided for information only. Please refer to our legal notice.
  • The following operating conditions were used to generate hot water output data for our products:
    • Supply water: 10°C
    • Primary water: 80°C (boilers), 85°C (water heaters) or 90°C (HeatMaster)
  • Operating conditions
    Cold water: 10°C
    Delta T° (outlet) : 30°C
    Data provided are indicative only. Please read the complete disclaimer.
Disclaimer
Learn more about our products

Site map | Legal notice | Glossary | FAQ
Contact ACV