- Dual application sealed combustion boiler of the indirect accumulation Tank-in-Tank type. Body completely insulated in rigid polyurethane foam
- Delta Performance 35 FV boiler with BMV1 transparent flame burner (low NOx)
- Delta Performance 50 FV boiler with BMV2 transparent flame burner (low NOx)
- Domestic hot water production of 291 to 328 litres in 10’ (Δt 30°C)
- 35 FV model: chimney connection diameter 80 mm or concentric 80/125 mm
- 50 FV model: chimney connection diameter 100 mm or concentric 100/150 mm
- Control panel with on/off switch, adjustable thermostat, Summer/Winter switch and pre-cut for ACV control unit (optional)
- Simple maintenance : easy access to flue pipes without dismounting air/flue connection
- Three high and low temperature heating connection kits available as an option to meet all current needs
- Several types of controls also available as an option
Main characteristics
 |
Input max. (heating) (kW) : |
50 |
 |
Output power max. (80/60°C) (kW) : |
46,8 |
 |
Capacity (total) (L) : |
162 |
 |
Dim. - Width or Diameter (w/o conn.) (mm) : |
542 |
 |
Dim. - Depth (w/o conn.) (mm) : |
800 |
 |
Dim. - Height (w/o conn.) (mm) : |
1830 |
 |
Peak flow at 40 °C (L/10’) : |
377 |
|