- Dual application sealed combustion boiler of the indirect accumulation Tank-in-Tank type. Body completely insulated in polyurethene rigid foam.
- Delta Performance (35 MV) modulating premix gas burner 10- 35 kW or premix on/off gas burner (35 SV) (BG 2000-S/35)
- Delta Performance (50 MV) modulating premix gas burner 15- 50 kW or premix on/off gas burner (50 SV) (BG-2000S/50)
- Domestic hot water production 291 to 328 litres in 10’ (Δt 30°C)
- Model 35 SV/MV : chimmey 80 mm or sealed combustion concentric 80/125 mm or bitube 80/80
- Model 50 SV/MV : chimmey 100 mm or or sealed combustion concentric 100/150 mm or bitube 100/100
- Control panel with on/off switch, adjustable thermostat, Summer/Winter switch and precut for ACV control unit (optional)
- Simple maintenance : easy access to flue pipes without dismounting air/flue connections
- Three high and low temperature heating connection kits available as an option to meet all current needs
- Several types of controls also available as an option
Main characteristics
 |
Input max. (heating) (kW) : |
34,9 |
 |
Output power max. (80/60°C) (kW) : |
31,9 |
 |
Capacity (total) (L) : |
127 |
 |
Dim. - Width or Diameter (w/o conn.) (mm) : |
542 |
 |
Dim. - Depth (w/o conn.) (mm) : |
800 |
 |
Dim. - Height (w/o conn.) (mm) : |
1585 |
 |
Peak flow at 40 °C (L/10’) : |
291 |
|