ACV Excellence in Hot water  >  ACV Hot water Tanks and Boilers  >  SolarMaster 30
Back 

SolarMaster 30

 Presentation Technical specifications Output data
Print


Product description (*)
SolarMaster 30
Floor installation Multi-energy (solar, heat pump, etc.) [ Legend ]
 
• Compact heating group for central heating and domestic hot water production, incorporating solar energy
• Condensing heat generator comprising:
- Premix burner, modulating from 6,5 kW up to 30 kW
- Self cleaning immersion heat exchanger, in stainless steel : low maintenance and high resistance to corrosion
•Multi-energy Tank-in-Tank for DHW production, with the inner stainlesssteel tank/heat exchanger and coil immersed in the primary water forthe solar heat source
• Primary circuit controlled by the MCBA,equipped with pump, expansion vessel, balanced header and 3-ways valvefor DHW priority.
• Full DHW circuit with thermostatic valve, expansion vessel and safety group
• Complete solar circuit with hydraulic elements, solar control box, expansion vessel, safety valve and temperature sensors
•The solar energy is used as well for DHW and central heating thanks tothe coil immersed in the primary tank and the 3-ways valved controlledby the solar controller
• The SolarMaster is ready to be connected to solid fuel boilers (stoves, wood or pellet boilers) or an electric heating element
•Two heating circuits with independent temperature control, withcirculator (1 installed, 1 optional), mixing 3-ways valve, supplysensor and control remotely monitored
• Remote control with climate control, to set the parameters in function of timer and outside sensor
 
Main characteristics
 
Input max. (heating) (kW) : 30
Input min. (heating) (kW) : 6,5
Output power max. (80/60°C) (kW) : 29,25
Efficiency (max. output) 80/60°C (%) : 97,5
Peak flow at 40 °C (L/10’) : 319
Max. absorbed heat (Heat source: boiler) (kW) : 25
Dim. - Width or Diameter (w/o conn.) (mm) : 1000
Dim. - Depth (w/o conn.) (mm) : 772
Dim. - Height (w/o conn.) (mm) : 1875
 
(*)
  • The product range offered can vary according to country. Please consult your distributor.
  • All values indicated on this site are provided for information only. Please refer to our legal notice.
  • The following operating conditions were used to generate hot water output data for our products:
    • Supply water: 10°C
    • Primary water: 80°C (boilers), 85°C (water heaters) or 90°C (HeatMaster)
  • Operating conditions
    Cold water: 10°C
    Delta T° (outlet) : 30°C
    Data provided are indicative only. Please read the complete disclaimer.