 Presentation Design characteristics Technical specifications Output data
Print


Product description (*)
HM 101
All Floor installation Gas [ key ]
 
  • High performance Domestic Hot Water (DHW) producer:
    - HeatMaster® 71: 646 litres in 10’, 2,133 litres in 60’, 1,835 litres continuous (Δt 30 °C)
    - HeatMaster® 101: 905 litres in 10’, 3,172 litres in 60’, 2,776 litres continuous (Δt 30 °C)
  • ACV BG 2000-M pre-mix modulating gas burner: natural gas, propane, butane compatible.
  • Modulation from 20 to 69.9 kW (HeatMaster® 71) or 25 to 107 kW (HeatMaster® 101). NIT burner with dual ignition-ionisation electrode
  • “MCBA" controller with 3 NTC sensors, one in the annular boiler detecting low DHW flows. Pre and post flushing timing control. Recirculation loop control. Three interfaces: user,
    installer, manufacturer. Self-diagnostic.
  • With all the features that distinguish the HeatMaster® range: central heating boiler, Tank-in-Tank, high domestic water temperature, temperature maintained at over 60°C
  • Duplex version for highly corrosive water.
  • Configuration in battery possible.
  • Duplex version availale on special request

 
Main characteristics
 
Input max. (heating) (kW) : 107
Input min. (heating) (kW) : 25
Output power max. (80/60°C) (kW) : 96,8
Capacity (total) (L) : 330
Dim. - Width or Diameter (w/o conn.) (mm) : 680
Dim. - Depth (w/o conn.) (mm) : 937
Dim. - Height (w/o conn.) (mm) : 2093
Peak flow at 40 °C (L/10’) : 905
 
(*)
  • The product range offered can vary according to country. Please consult your distributor.
  • All values indicated on this site are provided for information only. Please refer to our legal notice.
  • The following operating conditions were used to generate hot water output data for our products:
    • Supply water: 10°C
    • Primary water: 80°C (boilers), 85°C (water heaters) or 90°C (HeatMaster)
  • Operating conditions
    Cold water: 10°C
    Delta T° (outlet) : 30°C
    Data provided are indicative only. Please read the complete disclaimer.