Discover our solutions > HeatMaster 35 TC


HeatMaster 35 TC
Presentation
 
All Floor installation Gas [ Legend ]
 

Total condensing storage combination boiler - complies with Part L.

With the high levels of building insulation now in place in most properties, the requirements for heating output are reducing – and this trend is set to continue with some experts predicting a drop in the boiler load due to heating from around 75% to as low as 45%. At
the same time, hot water usage is increasing year-by year as demand rises for luxury bathing facilities such as high performance showers and spa baths. If hot
water demand has risen to 55% of the boiler load, the natural next step is to gain as much efficiency in hot water mode as possible.

MCBA electronic control fitted as standard. Managing boiler and burner functions, this helps reduce the stop/start cycle significantly, ultimately saving fuel and component wear and tear.

Additional controls available, please discuss your requirements with our technical department.

Key Benefits

  • Totally condensing in both hot water & heating - The best condensing combination boiler in the world
  • Dual primary circuit technology
  • Dual tank technology
  • Modulating premix gas burner
  • Weather compensation control
  • Exceptional hot water outputs in excess of 80 litres per minute
  • Suitable for connection to existing heating systems
  • Reduced maintenance due to self-cleaning heat exchanger






Main characteristics
 
Input max. (heating) (kW) : 34,9 (G20) - 30,6 (G31)
Input min. (heating) (kW) : 10 (G20-G31)
Output power max. (80/60°C) (kW) : 34,1 (G20) - 29,9 (G31)
Output power min. (80/60°C)) (kW) : 9,8 (G20-G31)
Efficiency (max. output) 80/60°C (%) : 97
Efficiency at 30% load (EN677) (%) : 107,5
Efficiency in DHW mode (Dt: 30K) (%) : 105,9
CO2 (max output) G20 (%) : 9,4
CO2 (min output) G20 (%) : 9,0
CO2 (max. output) G31 (%) : 10,5
CO2 (min. output) G31 (%) : 10,1
CO emissions (max.output) (mg/kWh) : 70 (G20) / 105 (G31)
CO emissions (min.output) (mg/kWh) : 6 (G20) / 17 (G31)
NOx emissions (max.output) (mg/kwh) : 59 (G20)
NOx emissions (min. output) (mg/kWh) : 29 (G20) / 31 (G31)
NOx emissions (weighted) (mg/kWh) : 40.3
NOx class (EN483) () : 5
Flue gas temperature at max.output 80/60°C (°C) : 60
Flue gas temperature at max.output 50/30°C (°C) : 35.3
Chimney: Max.pressure drop in flue pipe (Pa) : 130
Chimney: max. length of concentric flue pipe (m) : 20
Chimney connection Ø (mm) : 80/80 - 80/125
Chimney connection type () : B23(P)-C13(X)-C33(X)-C43(X)-C53(X)-C63(X)-C83(X)-C
Gas supply pressure G20/25 (mbar) : 20-25
Gas supply pressure G30/31 (mbar) : 30-37-50
Gas flow rate G20 (max.output) (m³/h) : 3,7
Gas flow rate G25 (max.output) (m³/h) : 4,3
Gas flow rate G31 (max.output) (kg/h) : 2.4
Capacity (primary) (L) : 86,5
Capacity (total) (L) : 186,5
Heating surface DHW tank (m²) : 2,2 + 0,6
Water pressure drop boiler at Δt = 20°C (mbar) : 30
Connection - heating (Ø) : 1" F
Connection - DHW (Ø) : 1" M
Connection - gas (Ø) : 3/4" M
Peak flow at 40 °C (L/10’) : 472
Peak flow 1st hour at 40 °C (L/60') : 1322
Continuous flow at 40°C (L/h) : 1070
Peak flow at 45 °C (L/10’) : 389
Peak flow 1st hour at 45 °C (L/60') : 1116
Continuous flow at 45 °C (L/h) : 917
Peak flow at 60 °C (L/10’) : 243
Peak flow 1st hour at 60 °C (L/60’) : 731
Continuous flow at 60 °C (L/h) : 642
Heating time from 10 to 80°C (Heat source: boiler) (min) : 37
Max. operating temperature (heating) (°C) : 90
Max. operating temperature (DHW) (°C) : 80
Max.service pressure heating (primary) (bar) : 3
Max.service pressure (DHW) (bar) : 10
Protection () : IP30
Operating voltage (50Hz) (V) : 230
Electrical current rating (A) : 0,8
Electrical consumption (W) : 184
Dim. - Width or Diameter (w/o conn.) (mm) : 600
Dim. - Depth (w/o conn.) (mm) : 670
Dim. - Height (w/o conn.) (mm) : 1700
Weight (empty) (kg) : 174
 


Design characteristics
 

Design characteristics
Legend 
  1. Gas connection
  2. Hot water outlet
  3. Heating supply
  4. Stainless steel Tank-in-Tank water store
  5. Primary heating circuit
  6. Heating return
  7. Cold water inlet
  8. Flue connection
  9. Premix modulating Burner
  10. Control panel
  11. Stainless steel heat exchanger
  12. Boiler shunt pomp
  13. Separation plate
  14. Stainless steel cold water pre-heating tank

 

 
 
Technical specifications (*)
 

Characteristics Value
 Input max. (heating)  34,9 (G20) - 30,6 (G31) kW
 Input min. (heating)  10 (G20-G31) kW
 Output power max. (80/60°C)  34,1 (G20) - 29,9 (G31) kW
 Output power min. (80/60°C))  9,8 (G20-G31) kW
 Efficiency (max. output) 80/60°C  97 %
 Efficiency at 30% load (EN677)  107,5 %
 Efficiency in DHW mode (Dt: 30K)  105,9 %
 CO2 (max output) G20  9,4 %
 CO2 (min output) G20  9,0 %
 CO2 (max. output) G31  10,5 %
 CO2 (min. output) G31  10,1 %
 CO emissions (max.output)  70 (G20) / 105 (G31) mg/kWh
 CO emissions (min.output)  6 (G20) / 17 (G31) mg/kWh
 NOx emissions (max.output)  59 (G20) mg/kwh
 NOx emissions (min. output)  29 (G20) / 31 (G31) mg/kWh
 NOx emissions (weighted)  40.3 mg/kWh
 NOx class (EN483)  5
 Flue gas temperature at max.output 80/60°C  60 °C
 Flue gas temperature at max.output 50/30°C  35.3 °C
 Chimney: Max.pressure drop in flue pipe  130 Pa
 Chimney: max. length of concentric flue pipe  20 m
 Chimney connection Ø  80/80 - 80/125 mm
 Chimney connection type  B23(P)-C13(X)-C33(X)-C43(X)-C53(X)-C63(X)-C83(X)-C
 Gas supply pressure G20/25  20-25 mbar
 Gas supply pressure G30/31  30-37-50 mbar
 Gas flow rate G20 (max.output)  3,7 m³/h
 Gas flow rate G25 (max.output)  4,3 m³/h
 Gas flow rate G31 (max.output)  2.4 kg/h
 Capacity (primary)  86,5 L
 Capacity (total)  186,5 L
 Heating surface DHW tank  2,2 + 0,6 m²
 Water pressure drop boiler at Δt = 20°C  30 mbar
 Connection - heating  1" F Ø
 Connection - DHW  1" M Ø
 Connection - gas  3/4" M Ø
 Peak flow at 40 °C  472 L/10’
 Peak flow 1st hour at 40 °C  1322 L/60'
 Continuous flow at 40°C  1070 L/h
 Peak flow at 45 °C  389 L/10’
 Peak flow 1st hour at 45 °C  1116 L/60'
 Continuous flow at 45 °C  917 L/h
 Peak flow at 60 °C  243 L/10’
 Peak flow 1st hour at 60 °C  731 L/60’
 Continuous flow at 60 °C  642 L/h
 Heating time from 10 to 80°C (Heat source: boiler)  37 min
 Max. operating temperature (heating)  90 °C
 Max. operating temperature (DHW)  80 °C
 Max.service pressure heating (primary)  3 bar
 Max.service pressure (DHW)  10 bar
 Protection  IP30
 Operating voltage (50Hz)  230 V
 Electrical current rating  0,8 A
 Electrical consumption  184 W
 Dim. - Width or Diameter (w/o conn.)  600 mm
 Dim. - Depth (w/o conn.)  670 mm
 Dim. - Height (w/o conn.)  1700 mm
 Weight (empty)  174 kg

Output data
 

Characteristics Value
 Peak flow at 40 °C  472 L/10’
 Peak flow 1st hour at 40 °C  1322 L/60'
 Continuous flow at 40°C  1070 L/h
 Peak flow at 45 °C  389 L/10’
 Peak flow 1st hour at 45 °C  1116 L/60'
 Continuous flow at 45 °C  917 L/h
 Peak flow at 60 °C  243 L/10’
 Peak flow 1st hour at 60 °C  731 L/60’
 Continuous flow at 60 °C  642 L/h
 Heating time from 10 to 80°C (Heat source: boiler)  37 min

 

(*)
  • The product range offered can vary according to country. Please consult your distributor.
  • All values indicated on this site are provided for information only. Please refer to our legal notice.
  • The following operating conditions were used to generate hot water output data for our products:
    • Supply water: 10°C
    • Primary water: 80°C (boilers), 85°C (water heaters) or 90°C (HeatMaster)
  • Operating conditions
    Cold water: 10°C
    Delta T° (outlet) : 30°C
    Data provided are indicative only. Please read the complete disclaimer.