️🚨 This product is no longer manufactured

The descriptions and diagrams below are for information only.

Portrait

Prestige 100 Solo

Wall hung gas fired condensing heat only boiler with stainless steel heat exchanger.

  • 10 Year Heat Exchanger Warranty
  • BIM Objects
  • Natural Gas and LPG
  • Domestic and Commercial
Short Energy Label Heating
  • label_energy_GAS
  • Boilers
  • Standard
  • Concentric
  • label_pose_icon_WB
# GTIN : 5400891001431
# P/N : 05648401
  • Easy to service and maintain with all components accessible from the front and flame inspection panel
  • Compact and lightweight
  • Integrated non return valve saves space above the boiler installation
  • Stainless steel heat exchanger for a long life, backed up by a 10-year heat exchanger warranty
  • Close load matching for more efficient use with a 6:1 turndown ratio
  • Simple to operate with integrated ACVMax controls LCD that can operate two heating circuits or a four boiler cascade
  • NEW optional pipework kits and low loss headers available – see pages 48
  • Supplied with LPG kit for easy on-site conversion
Schematic
  1. Concentric chimney connection 100/150mm with measuring element
  2. Chimney tube
  3. Modulating Air/gas premix burner
  4. Gas pressure switch
  5. Air inlet
  6. Condensate recovery dish
  7. Cold water return
  8. Safety valve
  9. Control panel with display and pressure gauge
  10. Pressure sensor
  11. Electrical panel.
  12. Stainless steel heat exchanger
  13. Water supply
  14. Auto air vent
  15. Flame sight glass
  16. Insulated casing
  17. Gas valve

Constructive characteristics

Capacity (total) 28 L
Capacity (primary) 28 L
Chimney: max length of concentric flue pipe 20 m
Chimney connection 100/150 Ømm
Connection - heating 1 ½ M Ø"
Connection gas 1 M Ø"
Primary flow 4300 L/h
Max operating temperature 87 °C
Water pressure drop boiler at Δt = 20°C 42 mbar
Max service pressure heating (primary) 4 bar
Weight (empty) 89 kg

Combustion

Input max (heating) HCV 109,89 kW
Input max (heating) LCV 99 kW
Efficiency at 30% load (EN15502-1) 108,1 %
Efficiency at 100% load (50/30°C) 105,6 %
Efficiency (max output) 80/60°C 97,46 %
CO emissions max output 66 ppm
NOx weighted (GCV) (EN15502) 34,2 mg/kWh
NOx class (EN15502) 6
Output power max (80/60°C) 97,5 kW
Output power min (80/60°C) 12,2 kW
Output power max (50/30°C) 104,5 kW
Gas flow rate (max output) 10,5 kg/h

Electrical Characteristics

Voltage 230 V
Frequency 50 Hz
Protection IP X4D
Electrical consumption 142 W

Eco Design Fields

Space heating energy efficiency class A
Seasonal space heating efficiency (35°C) 93 %
Sound power level indoors LWA 62 dB
Product Fiche

Technical brochure

ACVMax - Installers handbook for heating systems controlled with ACVMax (3.06-3.16)

21.45MB – en

ACVMax - Installers handbook for heating systems controlled with ACVMax (Software version 4.04 or more)

25.98MB – en

MCBA-5 - Instruction for the installer

3.62MB – en

Prestige - ACVMax - System control - For boilers produced in 2016 - Software version 3.03

13.58MB – en

Prestige 18 & 32 Solo / Excellence MKIII (2011)

5.50MB – en

Prestige 24 / 32 Solo / Excellence (v15) - Installation, operation and maintenance instructions

22.42MB – en

Prestige 42, 50, 75, 100, 120 Solo (v14) - Installation, operations and maintenance instructions

14.83MB – en

Prestige Solo 100 Data Sheet

427.25kB – en

Prestige Solo 42, 50, 75, 100, 120 (2014) - System Control ACVMax

11.36MB – en

System Control ACVMax for Prestige 2014 (models built before 2016)

13.32MB – en

Ecodesign

Product Fiche

BIM Files

BIM Files

Call ACV

Need some answers? Talk to a specialist

Tel. +44 (0)1383 820100