Cylinders

Jumbo

Jumbo 800

Fast recovery, high volume Tank-in-Tank hot water storage

  • TANK-IN-TANK TECHNOLOGY
  • For industrial applications

# 06648501

  • External heating source
  • Tanks
  • Floor installation
  • Tank-in-Tank floor standing indirect hot water storage tank.
  • Stainless steel construction - no need for sacrificial anodes.
  • High performance - fast heat up and rapid recovery.
  • Fully insulated - 120mm Rock wool insulation.
  • Stove enameled steel casing, supplied seperatley to enable the tank to pass through standard 800mm doorways.
  • Two sizes - 800 and 1000 litres.
  • Can be used in battery formation for high output installations.
  • Large heating surface area means reduced boiler cycling.
  • Anti-Legionella : Storage temperature > 60 ° C.
  1. Hot water outlet.
  2. Domestic cold water inlet.
  3. Thermometer.
  4. Control thermostat.
  5. Rockwool insulation - 120 mm.
  6. Stove enameled metal casing.
  7. Domestic Hot Water return /T+P Valve tapping
  8. Primary water flow connection
  9. Outer steel tank containing the primary fluid.
  10. Thermostat pocket
  11. Internal stainless steel tank.
  12. Primary water return connection

Constructive characteristics

Capacity (total) 800 L
Capacity (primary) 125 L
Weight (empty) 360 kg
Max operating temperature 85 °C
Max operating pressure heating (primary) 4 bar
Max operating pressure (DHW) 8,6 bar
Primary flow (EN 12897:2016) 2,08 L/s
Connection - primary 2 F Ø"
Connection - DHW 6/4 M Ø"
Connection - re-circulation / safety valve 6/4 M Ø"

Heating characteristics

Reheat time (EN 12897) - min
Reheat performance (EN 12897:2016) 82 kW
Max absorbed heat (Heat source: boiler) 100 kW

Domestic hot water performance

Peak flow at 40°C 1881 L/10’
Peak flow 1st hour at 40°C 4270 L/60’
Continuous flow at 40°C 2868 L/h
Peak flow at 45°C 1612 L/10’
Peak flow 1st hour at 45°C 3660 L/60’
Continuous flow at 45°C 2458 L/h
Peak flow at 60°C 961 L/10’
Peak flow 1st hour at 60°C 2124 L/60’
Continuous flow at 60°C 1395 L/h
Coefficient (NL) 67
Dimensions A 1955 mm
Dimensions B 1585 mm
    • Technical brochure

    • HRs - Jumbo ИНСТРУКЦИЯ ПО УСТАНОВКЕ, ЭКСПЛУАТАЦИИ И СЕРВИСНОМУ ОБСЛУЖИВАНИЮ, для пользователя и сервисного специалиста

    • 1.77 MB – ru

    • Technical brochure

    • HRs 321, 601, 800, 1000 / Jumbo 800, 1000 - Installation, operations and maintenance instructions

    • 2.45 MB – en

    • Marketing brochure

    • Jumbo 800 & 1000 Technical Manual UK

    • 2.45 MB – en

    • Marketing brochure

    • ACV Products Overview 2017

    • 3.96 MB – en

Eco Design Fields

Standing loss (Energy label) 142 W
    • Product Fiche

    • Jumbo 800

Other products

Jumbo 1000
Cylinders

Fast recovery, high volume Tank-in-Tank hot water storage

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20