Bi-energy cylinder to install vertically on the wall, equipped with a resistance of 2,2 kW placed in the primary to avoid limestone.

# 06623901

  • External heating source
  • Add-on electricity
  • Tanks
  • Wall installation
  • Domestic stainless steel cylinder with tank-in-Tank technology
  • BI-ENERGY : fitted with a 2,2 kW electrical element in the primary circuit to avoid scalding
  • 50 mm polyurethane foam insulation offers optimal energy performance
  • Thick polypropylene jacket. Hard wearing and shock resistant
  • 5 sizes: from 100 to 240 litres
  • Pre-mounted wall mounting kit
  • Integral thermostat control included (replaceable by a probe for use with an electronically controlled boiler)
  • Thermometer
  • 3.5 bar mains unvented kit and mixing valve supplied as standard
  • Anti-Legionella : Storage temperature > 60 ° C
  • 7 bar Ø 3/4” safety valve included
  • SYSTEM TANK-IN-TANK
  • 5 YEAR WARRANTY (see our terms of sale)
  • SMART FOR LIFE LIFETIME WARRANTY! (see conditions www.acv.com)

Legend

  1. Auxiliary connection DHW
  2. Cold water inlet connection
  3. Control thermostat
  4. Flow connection (primary circuit)
  5. Polyurethane foam insulation
  6. Return connection (primary circuit)
  7. Outer steel tank (primary circuit)
  8. Manual air bleed valve
  9. Hot water outlet connection
  10. Polypropylene top lid
  11. Stainless steel tank (DHW)
  12. Polypropylene shell
  13. Polypropylene bottom lid
  14. DHW thermometer
  15. Dry well
  16. Control panel
  17. Electric heating element 2200 W

Characteristics

Capacity (total) 242 L
Heating surface DHW tank 2,29
Capacity (domestic hot water) 200 L
Connection - primary 1 F inches
Connection - DHW 3/4 M inches
Connection - re-circulation / safety valve 3/4 M inches
Primary flow (ΔT10K) do not use 5500 L/h
Pressure drop (primary - ΔT10K) 51 mbar
Max operating temperature (primary) 90 °C
Max operating pressure (DHW) 8,6 bar
Max operating pressure (primary) 3 bar
Weight (empty) 87 kg

Hot water performances

Peak flow at 40°C 700 L/10’
Peak flow 1st hour at 40°C 2319 L/60’
Continuous flow at 40°C 1943 L/h
Peak flow 1st hour at 45°C 1988 L/60’
Continuous flow at 45°C 1665 L/h
Peak flow at 60°C 337 L/10’
Peak flow 1st hour at 60°C 1165 L/60’
Continuous flow at 60°C 994 L/h
Pre-heating time from 10 to 80°C (Heat source: boiler) 20 min
Warm-up time (10 to 60°C) with 2,2 kW heating element 397 min
Max absorbed heat (Heat source: boiler) 68 kW
Operating voltage 230 V
Electrical resistance 2200 kW
Max design pressure (DHW) 10 bar
A 1744 mm
B 1508 mm
C 1244 mm
Dim. - Height (with conn.) 1744 mm
Dim. - Height (w/o conn.) 1680 mm
Dim. - Width or Diameter (w/o conn.) 565 mm

Other products

Smart 240
Cylinders

Multiposition tank. Can be placed on the floor or vertically on the wall.

Smart E Plus 240
Cylinders

Fast recovery Tank-in-tank cylinder with the addition of multiple ports allowing flexible installati...

Smart 600
Cylinders

Fast recovery Tank-in-Tank Cylinder - perfect partner to a condensing boiler

Smart 210
Cylinders

Multiposition tank. Can be placed on the floor or vertically on the wall.

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20