Portrait

HeatMaster® 60 N

High performance, combined direct fired boiler and water heater

  • TANK-IN-TANK TECHNOLOGY
  • label_energy_FUEL
  • Boilers
  • DHW Production
  • Standard
  • Floor installation
# GTIN : 5400891032299
# P/N : A1002067
Label 2
  • Stainless steel tank-in-tank design
  • Can also be used as a stand alone water heater
  • Choice of Burner: Low NOx premix gas or LPG, forced draught natural gas or LPG or pressure jet 28 sec or 35 sec oil.
  • Anti-Legionellae: Hot water stored at a consistently high temperature
  • Built in Primary circuit shunt high efficiency pump
  • Body completely insulated in rigid polyurethane foam
  • Stove enameled casing
  • No need for sacrificial anodes
  • Control panel with Control Thermostat, T+P Gauge, Time Clock, Manual reset high limit thermostat, On/Off Switch, Summer/Winter Switch
  • Most heating demands can be met by connecting two or more HeatMasters together
  • The HeatMaster can be used in conjunction with the Smart, HRs, HRi or Jumbo hot water storage tanks, supplying even the largest hot water requirement
  • Non Ecodesign compliant
Schematic
  1. Limit thermostat 95 °C / Thermometer / Thermostat Security 103 °C.
  2. Cold water inlet.
  3. Removable front casing.
  4. Rigid polyurethane insulation.
  5. High efficiency boiler charging pump.
  6. Control Thermostat.
  7. Burner cover.
  8. Burner (not provided)
  9. Flue reduction collar.
  10. Top metal casing.
  11. Heating circuit outlet.
  12. Domestic hot water outlet.
  13. Internal stainless steel tank.
  14. Flue pipes and turbulators
  15. External steel tank containing the primary fluid.
  16. Heating circuit return
  17. Primary circuit drain valve
  18. Combustion chamber
  19. Steel base

Constructive characteristics

Capacity (total) 151 L
Capacity (primary) 68 L
Capacity (domestic hot water) 83 L
Capacity expansion tank(s) 1 x 8 L
Chimney connection 150 Ømm
Connection - heating 1 ½ F Ø"
Connection - DHW 3/4 M Ø"
Connection - safety valve 1/2 M Ø"
Max operating temperature 90 °C
Water pressure drop boiler at Δt = 20°C 54 mbar
Max service pressure heating (primary) 3 bar
Max service pressure (DHW) 8,6 bar
Weight (empty) 220 kg

Heating characteristics

Heating time from 10 to 90°C 17 min

Combustion

Input max (heating) HCV 77,7 kW
Input max (heating) LCV 69,9 kW
Efficiency at 30% load (EN15502-1) 96,0 %
Efficiency (max output) 80/60°C 90,1 %
NOx weighted (GCV) (EN15502) 83,3 mg/kWh
NOx class (EN15502) 5
Output power max (80/60°C) 63 kW

Domestic hot water performance

Peak flow at 40°C 474 L/10’
Peak flow 1st hour at 40°C 2046 L/60’
Continuous flow at 40°C 1835 L/h
Peak flow at 45°C 378 L/10’
Peak flow 1st hour at 45°C 1777 L/60’
Continuous flow at 45°C 1573 L/h
Peak flow at 60°C 245 L/10’
Peak flow 1st hour at 60°C 1206 L/60’
Continuous flow at 60°C 1101 L/h

Electrical Characteristics

Voltage 230 V
Frequency 50 Hz
Protection IP 30
Electrical consumption 82 W
Electrical power requirements 0,4 A

Technical brochure

Addendum HeatMaster 200N-200F (V13)

498.83kB

Burner BG2000-M 201 installation instructions

2.99MB

Burner_assembly_instructions HM 201

2.50MB

Casing Assembly Instructions HeatMaster 201 v17

10.28MB

HM 30-100 N - Technical manual

2.49MB

HeatMaster 201 (v17) - Installation, operations and maintenance instructions

8.33MB – en

HeatMaster (1999) - Installations-, Bedienungs- und Wartungsanleitung

4.82MB – en de

HeatMaster 200 N / 200 F (v13) : Installation, operation and maintenance instructions

3.89MB – en

HeatMaster 200 N / 200 F (v13) : ИНСТРУКЦИЯ ПО УСТАНОВКЕ, ЭКСПЛУАТАЦИИ И СЕРВИСНОМУ ОБСЛУЖИВАНИЮ

3.92MB – ru

HeatMaster 201 Booster - Assembling and installation instructions

723.11kB – en

HeatMaster 71, 101, 201 (v13) - Installation, operations and maintenance instructions

6.07MB – en

HeatMaster 71-101-201 (V13)

6.10MB – ru

HeatMaster N - Installation, operations and maintenance instructions - v2013

4.69MB – ru

HeatMaster N - Installation, operations and maintenance instructions - v2013

4.64MB – en

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20