High Efficiency Boilers

HeatMaster N

HeatMaster® 200 N

High performance combined boiler and water heater

# A1002072

  • Fuel
  • Boilers
  • Standard
  • Floor installation
  • Stainless steel tank-in-tank design
  • Comprises a primary circuit which may also be used for a heating circuit.
  • Body completely insulated in 50mm rigid polyurethane foam.
  • Various fuel options, the HeatMaster ® 200 N comes with Gas, Oil, LPG or propane options.
  • The HeatMaster ® 200 F is equipped with matched oil burner adapted to the combustion chamber of the boiler. The burner output on the HM200F model is increased to 196 kilowatts input.
  • Build in primary circuit shunt *****HEP*******pumps, Primary expansion vessels, safety valve and low water safety switch.
  • Control panel with main switch, summer / winter switch, time clock, control thermostat and combined temperature and pressure gauge, primary low water pressure indicator, burner lockout indicator, high limit cut off indicator and manual reset high limit thermostat.
  • TANK-IN-TANK TECHNOLOGY

Legend

  1. Flue reducer (vertical output option available).
  2. Domestic cold water inlet.
  3. Thermostat pocket.
  4. Connection for T+P valve ( optional).
  5. Automatic air vent.
  6. Rigid polyurethane foam insulation.
  7. Internal stainless steel tank.
  8. Low water pressure switch.
  9. Thermostat pocket.
  10. Control stat pocket
  11. HEP Boiler charge pump (X2).
  12. Thermostat pocket for ECS probe.
  13. Hot water flow.
  14. Heating flow.
  15. Primary expansion vessel (4x).
  16. Flue ways and turbulators.
  17. Heating return.
  18. Drain valve.
  19. Primary safety valve.
  20. Primary circuit.
  21. Combustion chamber.

Characteristics

Capacity (total) 641 L
Heating surface DHW tank 5,3
Capacity (domestic hot water) 400 L
Connection - DHW 2 M inches
Max operating temperature 90 °C
Max service pressure (DHW) 8,6 bar
Max service pressure heating (primary) 3 bar
Weight (empty) 628 kg

Hot water performances

Peak flow at 40°C 1570 L/10’
Peak flow 1st hour at 40°C 4920 L/60’
Continuous flow at 40°C 4020 L/h
Peak flow 1st hour at 45°C 4221 L/60’
Continuous flow at 45°C 3446 L/h
Peak flow at 60°C 915 L/10’
Peak flow 1st hour at 60°C 2925 L/60’
Continuous flow at 60°C 2412 L/h
Pre-heating time from 10 to 80°C (Heat source: boiler) 29 min
Input max (heating) LCV 154 kW
Input max (heating) HCV 171,1 kW
Output power max (80/60°C) 141,7 kW
Connection - heating 2 F Ø inches
Water pressure drop boiler at Δt = 20°C 118 mbar
Chimney connection 250 Ø mm
Operating voltage 230 V
Protection IP 30
Electrical consumption 425 W
Operating voltage 218.5;241.5 bar
Capacity expansion tank(s) 4 x 8 L
Dim. - Depth (w/o conn.) 1044 mm
Dim. - Height (w/o conn.) 2085 mm
Dim. - Width or Diameter (w/o conn.) 1020 mm
Dim. - Depth (with conn.) 1080 mm
Dim. - Height (with conn.) 2370 mm
Dim. - Width or Diameter (with conn.) 1020 mm
    • Technical brochure

    • HeatMaster 71, 101, 201 (v13) - Installation, operations and maintenance instructions

    • 5.79 MB – en

    • Technical brochure

    • Addendum HeatMaster 200N-200F (V13)

    • 487 KB –

    • Technical brochure

    • HeatMaster N - Installation, operations and maintenance instructions - v2013

    • 8.08 MB – ru

    • Technical brochure

    • Casing Assembly Instructions HeatMaster 201 v17

    • 9.89 MB –

    • Technical brochure

    • HeatMaster 71-101-201 (V13)

    • 5.81 MB – ru

    • Technical brochure

    • HeatMaster 200 N / 200 F (v13) : ИНСТРУКЦИЯ ПО УСТАНОВКЕ, ЭКСПЛУАТАЦИИ И СЕРВИСНОМУ ОБСЛУЖИВАНИЮ

    • 5.04 MB – ru

    • Technical brochure

    • HeatMaster 201 (v17) - Installation, operations and maintenance instructions

    • 7.76 MB – en

    • Technical brochure

    • HeatMaster 200 N / 200 F (v13) : Installation, operation and maintenance instructions

    • 5.04 MB – en

    • Technical brochure

    • HeatMaster 201 Booster - Assembling and installation instructions

    • 761 KB – en

    • Technical brochure

    • HeatMaster N - Installation, operations and maintenance instructions - v2013

    • 8.06 MB – en

    • Technical brochure

    • Burner BG2000-M 201 installation instructions

    • 2.84 MB –

    • Marketing brochure

    • ACV Products Overview 2017

    • 3.96 MB – en

Other products

HeatMaster® 30 N
High Efficiency Boilers

High performance, combined direct fired boiler and water heater

HeatMaster® 200 F
High Efficiency Boilers

High performance combined boiler and water heater

HeatMaster® 70 N
High Efficiency Boilers

High performance combined boiler and water heater

HeatMaster 71
High Efficiency Boilers

High performance fully modulating combined boiler and water heater

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20