Commercial combi boiler combining all the benefits of domestic combi boiler technology while comfortably meeting peak commercial DHW demands.
Space and time saving solution due to not needing to install separate boiler and hot water cylinders.
ErP Class A, NOx levels significantly under 40 mg/kWh and operating efficiencies well above the minimum requirements of Part L (2022) ensure an energy efficient installation.
Internal time clock offers the capability to set up to 6 programmes within a 24 hour period to ensure that fuel usage is managed as efficiently as possible.
Multiple controls options - On/Off, 0-10V power OR temperature control, BMS communication via Modbus.
Corrosion-resistant stainless steel heat exchanger and tank reduces maintenance and increases system lifespan
Suited to high demand and critical hot water premises such as hotels and hospitals
Operates in most efficient mode (condensing) for both heating and hot water
Integrated legionella protection
Supplied with LPG kit for simple on-site conversion
BIM & CAD objects available
Concentric flue gas/air inlet box
Flue gas exhaust tube
Combustion chamber
Stainless steel heat exchanger
Stainless steel “Tank-in-Tank” hot water production tank
Primary circuit separation disc
Indirect water pre-heater
Insulation
Condensate recovery dish + NTC5 sensor (flue gas)
High efficiency circulator pump
NTC2 sensor (CH return)
Electrical panel (with spare fuses at the back)
ACVMax Touch Control panel
On-Off switch
DHW tank dry well (Dip tube with temperature sensor)
Automatic air vent
Gas pipe
NTC1 sensor (CH supply)
Gas valve
DHW safety valve / (T&P relief valve - UK only)
Modulating air/gas premix burner with fan
Air inlet
DHW outlet
DHW recirculation tube
Constructive characteristics
HeatMaster 25 Evo 2
HeatMaster 35 Evo 2
HeatMaster 45 Evo 2
Capacity (total)
L
196
196
196
L
Capacity (primary)
L
100
100
100
L
Capacity (domestic hot water)
L
96
96
96
L
Chimney: Max pressure drop in flue pipe
Pa
130
130
130
Pa
Chimney: max length of concentric flue pipe
m
20
20
20
m
Chimney connection
Ømm
80/125
80/125
80/125
Ømm
Connection - heating
Ø"
1 F
1 F
1 F
Ø"
Connection - DHW
Ø"
1 M
1 M
1 M
Ø"
Connection gas
Ø"
3/4 M
3/4 M
3/4 M
Ø"
Connection - re-circulation / safety valve
Ø"
na / 1 F
na / 1 F
na / 1 F
Ø"
Connection - safety valve
Ø"
1/2M
1/2M
1/2M
Ø"
Max operating temperature
°C
87
87
87
°C
Water pressure drop boiler at Δt = 20°C
mbar
3
6
10
mbar
Max service pressure heating (primary)
bar
3
3
3
bar
Max service pressure (DHW)
bar
8,6
8,6
8,6
bar
Height when tilted
mm
1880
1880
1880
mm
Weight (empty)
kg
177
177
177
kg
Heating characteristics
HeatMaster 25 Evo 2
HeatMaster 35 Evo 2
HeatMaster 45 Evo 2
Pre-heating time from 10 to 80°C (Heat source: boiler)
min
35
26
23
min
Reheat time from 40 to 90°C
min
30
28
25
min
Reheat time from 40 to 80°C
min
22
22
16
min
Heating time from 10 to 90°C
min
43
33
30
min
Combustion
HeatMaster 25 Evo 2
HeatMaster 35 Evo 2
HeatMaster 45 Evo 2
Input max (heating) HCV
kW
27.8
38.7
50.6
kW
Input max (heating) LCV
kW
25
35
45
kW
Combustion efficiency
%
98.2
98.2
97.9
%
Efficiency at 30% load (EN15502-1)
%
109,0
109,0
109,0
%
Efficiency at 100% load (50/30°C)
%
103,9
103,9
103,9
%
Efficiency (max output) 80/60°C
%
98
98
98
%
Efficiency (min output) 80/60°C
%
98
98
98
%
Efficiency DHW mode ΔT 30K
%
105.4
105.4
103.1
%
CO emissions max output
ppm
27
48
63
ppm
CO emissions min output
ppm
6
4
4
ppm
Mass rate of combustion products (gas)
kg/h
42
57
75
kg/h
NOx weighted (GCV) (EN15502)
mg/kWh
24.6
29.5
33.2
mg/kWh
NOx class (EN15502)
6
6
6
Output power max (80/60°C)
kW
24.3
34.1
44.1
kW
Output power min (80/60°C)
kW
4.9
6.8
8.8
kW
Gas flow rate (min output)
m³/h
0.52
0.73
0.93
m³/h
Domestic hot water performance
HeatMaster 25 Evo 2
HeatMaster 35 Evo 2
HeatMaster 45 Evo 2
Peak flow at 40°C
L/10’
361
408
451
L/10’
Peak flow 1st hour at 40°C
L/60’
1018
1328
1610
L/60’
Continuous flow at 40°C
L/h
788
1104
1390
L/h
Peak flow at 45°C
L/10’
301
339
373
L/10’
Peak flow 1st hour at 45°C
L/60’
865
1127
1366
L/60’
Continuous flow at 45°C
L/h
676
946
1192
L/h
Peak flow at 60°C
L/10’
183
197
224
L/10’
Peak flow 1st hour at 60°C
L/60’
577
749
894
L/60’
Continuous flow at 60°C
L/h
473
662
820
L/h
Electrical Characteristics
HeatMaster 25 Evo 2
HeatMaster 35 Evo 2
HeatMaster 45 Evo 2
Voltage
V
230
230
230
V
Frequency
Hz
50
50
50
Hz
Protection IP
20
20
20
Electrical consumption
W
101
111
126
W
Electrical power requirements
A
0.7
0.8
0.85
A
Eco Design Fields
HeatMaster 25 Evo 2
HeatMaster 35 Evo 2
HeatMaster 45 Evo 2
Space heating energy efficiency class
A
A
A
Seasonal space heating efficiency (35°C)
%
93
93
93
%
Declared load profile
XXL
XXL
XXL
Water heating energy efficiency class
A
A
A
Water heating energy efficiency [ηwh] (EU 814/2013 Art 2 (15) Ann.IV-3)