Previous product
Portrait

HR s 1000

Fast recovery stainless steel tank-in-tank cylinder

  • TANK-IN-TANK TECHNOLOGY
  • label_energy_EXT
  • Tanks
  • Floor installation
# GTIN : 5400891002049
# P/N : 06633101
Label 2
  • Tank-in-Tank floor standing indirect hot water storage tank.
  • Stainless steel construction - no need for sacrificial anodes.
  • High performance - fast heat up and rapid recovery.
  • Low heat loss - 100mm polyurethane insulation foam
  • Can be used in battery formation for high output installations.
  • Large heating surface area means reduced boiler cycling.
  • Anti-Legionella : Storage temperature > 60 °C
Schematic
  1. DHW return or temp/pressure relief valve connection.
  2. Manual air vent.
  3. Cold water inlet connection.
  4. Rigid top case.
  5. Stainless steel thermostat pocket.
  6. 100mm flexible polyurethane foam insulation.
  7. Outer shell vinyl jacket.
  8. DHW return connection.
  9. Primary inlet connection.
  10. Internal stainless steel DHW tank.
  11. External Tank (primary) steel.
  12. Primary return connection.

Constructive characteristics

HR s 320 HR s 600 HR s 800 HR s 1000
Capacity (total) L 318 606 800 1000 L
Capacity (primary) L 55 161 125 160 L
Weight (empty) kg 106 201 261 308 kg
Max operating temperature °C 85 85 85 85 °C
Max operating pressure heating (primary) bar 4 4 4 4 bar
Max operating pressure (DHW) bar 8,6 8,6 8,6 8,6 bar
Primary flow (EN 12897:2016) L/s 1,81 2,08 2,08 2,08 L/s
Primary heater pressure drop (EN12897:2016) mbar 99 92 75 60 mbar
Connection - primary Ø" 2 F 2 F 2 F 2 F Ø"
Connection - DHW Ø" 1 ½ M 1 ½ M 1 ½ M 1 ½ M Ø"
Connection - re-circulation / safety valve Ø" 1 ½ M 1 ½ M 1 ½ M 1 ½ M Ø"

Heating characteristics

HR s 320 HR s 600 HR s 800 HR s 1000
Reheat time (EN 12897) min - - - - min
Reheat performance (EN 12897:2016) kW 60 71 82 97 kW
Max absorbed heat (Heat source: boiler) kW 76 88 100 112 kW

Domestic hot water performance

HR s 320 HR s 600 HR s 800 HR s 1000
Peak flow at 40°C L/10’ 922 1345 1881 2265 L/10’
Peak flow 1st hour at 40°C L/60’ 2732 3437 4270 4940 L/60’
Continuous flow at 40°C L/h 2172 2511 2868 3210 L/h
Peak flow at 45°C L/10’ 790 1153 1612 1941 L/10’
Peak flow 1st hour at 45°C L/60’ 2342 2946 3660 4234 L/60’
Continuous flow at 45°C L/h 1862 2152 2458 2751 L/h
Peak flow at 60°C L/10’ 504 706 961 1145 L/10’
Peak flow 1st hour at 60°C L/60’ 1402 1733 2124 2438 L/60’
Continuous flow at 60°C L/h 1077 1232 1395 1562 L/h
Coefficient (NL) 18 34 67 87

Eco Design Fields

HR s 320 HR s 600 HR s 800 HR s 1000
Standing loss (Energy label) W 97 123 137 146 W
Product Fiche
HR s 320 HR s 600 HR s 800 HR s 1000
Dimensions A (mm) 1600 1895 1955 2355 (mm)
Dimensions B (mm) 559 703 780 780 (mm)
Dimensions C (mm) 255 255 335 335 (mm)
Dimensions D (mm) 1285 1585 1585 1985 (mm)
Dimensions E (mm) 760 905 - - (mm)

Technical brochure

GL / HR / HR BE / JUMBO (1999)

3.88MB – en de

HRs - Jumbo ИНСТРУКЦИЯ ПО УСТАНОВКЕ, ЭКСПЛУАТАЦИИ И СЕРВИСНОМУ ОБСЛУЖИВАНИЮ, для пользователя и сервисного специалиста

6.60MB – ru

HRs 321, 601, 800, 1000 / Jumbo 800, 1000 - Installation, operations and maintenance instructions

6.65MB – en

Technical manual kit thermostat soft jacket (A1004714 - 027000)

2.01MB

Thermostat mounting kit

506.07kB

Marketing brochure

ACV Guide to Ecodesign and Energy Labelling

969.34kB – en

Ecodesign

Product Fiche

BIM Files

BIM Files

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20