Constructive characteristics |
||
|---|---|---|
| Capacity (total) | 24,7 | L |
| Capacity (primary) | 24,7 | L |
| Chimney: Max pressure drop in flue pipe | 300 | Pa |
| Chimney connection | 250 | Ømm |
| Air intake connection | 150 | Ømm |
| Connection - heating | DN100 | Ø" |
| Connection gas | 1 1/2 M | Ø" |
| Primary flow | 21900 | L/h |
| Max operating temperature | 90 | °C |
| Max service pressure heating (primary) | 6 | bar |
| Pressure drop (primary - ΔT10K) | 220 | mbar |
| Weight (empty) | 429 | kg |
Combustion |
||
| Input max (heating) HCV | 566,1 | kW |
| Input max (heating) LCV | 510 | kW |
| Efficiency at 30% load (EN15502-1) | 108,1 | % |
| Efficiency at 100% load (50/30°C) | 103,1 | % |
| Efficiency (max output) 80/60°C | 97,2 | % |
| Efficiency (min output) 80/60°C | 97 | % |
| CO emissions max output | 93,1 | ppm |
| NOx class (EN15502) | 6 | |
| Output power max (80/60°C) | 495,7 | kW |
| Output power min (80/60°C) | 99 | kW |
| Gas flow rate (min output) | 10,8 | m³/h |
Electrical Characteristics |
||
| Voltage | 230 | V |
| Frequency | 50 | Hz |
| Protection IP | 00B | |
| Electrical consumption | 2300 | W |
| Electrical power requirements | 10 | A |
| Dimensions A | 1553 | (mm) |
|---|---|---|
| Dimensions B | 208,5 | (mm) |