The descriptions and diagrams below are for information only.
                        Constructive characteristics | 
                    ||
|---|---|---|
| Capacity (total) | 290 | L | 
| Capacity (primary) | 160 | L | 
| Capacity (domestic hot water) | 130 | L | 
| Capacity expansion tank(s) | 2 x 10 | L | 
| Chimney connection | 150 | Ømm | 
| Connection - heating | 1 ½ F | Ø" | 
| Connection - DHW | 1 M | Ø" | 
| Connection - safety valve | 1/2 M | Ø" | 
| Max operating temperature | 90 | °C | 
| Water pressure drop boiler at Δt = 20°C | 83 | mbar | 
| Max service pressure heating (primary) | 3 | bar | 
| Max service pressure (DHW) | 8,6 | bar | 
| Weight (empty) | 320 | kg | 
                        Heating characteristics | 
                    ||
| Pre-heating time from 10 to 80°C (Heat source: boiler) | 21 | min | 
| Heating time from 10 to 90°C | 36 | min | 
                        Combustion | 
                    ||
| Input max (heating) HCV | 118,9 | kW | 
| Input max (heating) LCV | 107 | kW | 
| Efficiency at 30% load (EN15502-1) | 96,4 | % | 
| Efficiency (max output) 80/60°C | 90,5 | % | 
| NOx weighted (GCV) (EN15502) | 99,9 | mg/kWh | 
| NOx class (EN15502) | 5 | |
| Output power max (80/60°C) | 96,3 | kW | 
                        Domestic hot water performance | 
                    ||
| Peak flow at 40°C | 898 | L/10’ | 
| Peak flow 1st hour at 40°C | 3168 | L/60’ | 
| Continuous flow at 40°C | 2776 | L/h | 
| Peak flow at 45°C | 774 | L/10’ | 
| Peak flow 1st hour at 45°C | 2676 | L/60’ | 
| Continuous flow at 45°C | 2379 | L/h | 
| Peak flow at 60°C | 510 | L/10’ | 
| Peak flow 1st hour at 60°C | 1811 | L/60’ | 
| Continuous flow at 60°C | 1665 | L/h | 
                        Electrical Characteristics | 
                    ||
| Voltage | 230 | V | 
| Frequency | 50 | Hz | 
| Protection IP | 30 | |
| Electrical consumption | 95 | W | 
| Electrical power requirements | 0,4 | A | 
A keyword, a reference, a range, a product,...