The descriptions and diagrams below are for information only.
Constructive characteristics |
||
---|---|---|
Capacity (total) | 290 | L |
Capacity (primary) | 160 | L |
Capacity (domestic hot water) | 130 | L |
Capacity expansion tank(s) | 2 x 10 | L |
Chimney connection | 150 | Ømm |
Connection - heating | 1 ½ F | Ø" |
Connection - DHW | 1 M | Ø" |
Connection - safety valve | 1/2 M | Ø" |
Max operating temperature | 90 | °C |
Water pressure drop boiler at Δt = 20°C | 83 | mbar |
Max service pressure heating (primary) | 3 | bar |
Max service pressure (DHW) | 8,6 | bar |
Weight (empty) | 320 | kg |
Heating characteristics |
||
Pre-heating time from 10 to 80°C (Heat source: boiler) | 21 | min |
Heating time from 10 to 90°C | 36 | min |
Combustion |
||
Input max (heating) HCV | 118,9 | kW |
Input max (heating) LCV | 107 | kW |
Efficiency at 30% load (EN15502-1) | 96,4 | % |
Efficiency (max output) 80/60°C | 90,5 | % |
NOx weighted (GCV) (EN15502) | 99,9 | mg/kWh |
NOx class (EN15502) | 5 | |
Output power max (80/60°C) | 96,3 | kW |
Domestic hot water performance |
||
Peak flow at 40°C | 898 | L/10’ |
Peak flow 1st hour at 40°C | 3168 | L/60’ |
Continuous flow at 40°C | 2776 | L/h |
Peak flow at 45°C | 774 | L/10’ |
Peak flow 1st hour at 45°C | 2676 | L/60’ |
Continuous flow at 45°C | 2379 | L/h |
Peak flow at 60°C | 510 | L/10’ |
Peak flow 1st hour at 60°C | 1811 | L/60’ |
Continuous flow at 60°C | 1665 | L/h |
Electrical Characteristics |
||
Voltage | 230 | V |
Frequency | 50 | Hz |
Protection IP | 30 | |
Electrical consumption | 95 | W |
Electrical power requirements | 0,4 | A |
A keyword, a reference, a range, a product,...