️🚨 This product is no longer manufactured

The descriptions and diagrams below are for information only.

Portrait

Prestige 32 Solo

High efficiency wall mounted condensing gas boiler. Stainless steel construction with self-cleaning flue ways.

  • Also available in propane
Short Energy Label Heating
  • label_energy_GAS
  • Boilers
  • Standard
  • Concentric
  • label_pose_icon_WB
# GTIN : 5400891001400
# P/N : 05648001
Label 2
  • New internal design for easy access to components and controls.
  • Self-cleaning flue ways
  • Modulation 1 to 6 and a high efficiency over the entire operating range, even at low power.
  • Stainless steel heat exchanger for high temperatures: unparalleled resistance to corrosion.
  • Premix burner.
  • Compact and lightweight.
  • 12 litre internal heating expansion vessel.
  • Hydraulic kits and controls options available
  • Offers exceptional performance in heating and hot water when installed with an ACV Smartline tank-in-tank cylinder
  • Ready for hydraulic connection to an external DHW tank.
  • Concentric flue connection 60/100. May also be connected in 80/125 or 80/80.
  • Can control two different circuits
Schematic
  1. Concentric chimney connection 60 /100mm with measuring element
  2. Chimney tube
  3. 12 liter expansion vessel (heating circuit)
  4. Stainless steel heat exchanger
  5. High efficiency circulator pump
  6. Heating return
  7. Control panel with display and pressure gauge
  8. Connection for external DHW tank
  9. Heating supply
  10. Exchanger return multifunctional quickconnection block (see detail view next page).
  11. Electrical panel (with spare fuses at the back).
  12. Built-in 3-way valve
  13. Gas valve assembly
  14. Silencer
  15. Auto air vent (heating circuit)
  16. Flame sight glass
  17. Insulated casing
  18. Modulating air/gas premix burner with fan

Constructive characteristics

Capacity (total) 8 L
Capacity (primary) 8 L
Capacity expansion tank(s) 12 L
Chimney: Max pressure drop in flue pipe 160 Pa
Chimney: max length of concentric flue pipe 16 m
Chimney connection 60/100 Ømm
Connection - heating 1 M Ø"
Connection gas 3/4 M Ø"
Primary flow 1400 L/h
Max operating temperature 87 °C
Water pressure drop boiler at Δt = 20°C 141 mbar
Max service pressure heating (primary) 3 bar
Weight (empty) 54 kg

Combustion

Input max (heating) HCV 35,52 kW
Input max (heating) LCV 32 kW
Efficiency at 30% load (EN15502-1) 109 %
Efficiency at 100% load (50/30°C) 106,3 %
Efficiency (max output) 80/60°C 97 %
CO emissions max output 88 ppm
NOx weighted (GCV) (EN15502) 35,6 mg/kWh
NOx class (EN15502) 6
Output power max (80/60°C) 31,0 kW
Output power min (80/60°C) 4,7 kW
Output power max (50/30°C) 34 kW
Gas flow rate (max output) 3,3 kg/h

Electrical Characteristics

Voltage 230 V
Frequency 50 Hz
Protection IP X4D
Electrical consumption 90 W

Eco Design Fields

Space heating energy efficiency class A
Seasonal space heating efficiency (35°C) 93 %
Sound power level indoors LWA 58 dB
Energy Label
Product Fiche

Technical brochure

Prestige

13.75MB – ru

Prestige 42, 50, 75, 100, 120 Solo (v14) - Installation, operations and maintenance instructions

14.83MB – en

ИНСТРУКЦИЯ ПО УСТАНОВКЕ, ЭКСПЛУАТАЦИИ И СЕРВИСНОМУ ОБСЛУЖИВАНИЮ, Для пользователя и сервисного специалиста - 2015

20.09MB – ru

System Control ACVMax for Prestige 2014 (models built before 2016)

13.32MB – en

Prestige [V14] - System Control ACVMAX

13.71MB

Prestige Solo 42-50-75-100-120 (V14) - Technical manual in Russian

15.50MB – ru

Prestige Solo 42, 50, 75, 100, 120 (2014) - System Control ACVMax

11.36MB – en

Prestige Box : installation, operation and maintenance instructions for the Installer and the User

5.89MB – en

Prestige 24 / 32 Solo / Excellence (v15) - Installation, operation and maintenance instructions

22.42MB – en

ACVMax - Installers handbook for heating systems controlled with ACVMax (3.06-3.16)

21.45MB – en

Prestige 18-32 [mk3] - Technical Manual

5.51MB

Prestige 18 - 32 Návod k instalaci, obsluze a údržbě

5.85MB

Prestige 18 & 32 Solo / Excellence MKIII (2011)

5.50MB – en

Prestige - ACVMax - System control - For boilers produced in 2016 - Software version 3.03

13.58MB – en

MCBA-5 - Instruction for the installer

3.62MB – en

ACVMax for Prestige Solo 42-50-75-100-120 (V14) - Technical manual in Russian

11.38MB – ru

ACVMax - Installers handbook for heating systems controlled with ACVMax (Software version 4.04 or more)

25.98MB – en

Marketing brochure

Prestige

19.48MB – en

ACV Guide to Ecodesign and Energy Labelling

969.34kB – en

Ecodesign

Energy Label

Product Fiche

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20